Posted by joespagetti |
12/16/2007 8:41 PM | remove |
It's a wonder the place didn't burn down. Yikes!
|
|
Posted by THWN2 |
11/11/2022 1:23 AM | remove |
HM double tapped mains= 125 amps not 60 thats there, 30 amp fuses where there should be only 15 amp & indoor fuse boxes where there should be rain proof 3R boxes? They didnt even bother to use a connector on that UNFUSED jumper between the boxes and some of the branch circuits let alone strapping the cables down, open knockouts. This is an electricians nightmare. This is so dangerous I could just see them carrying the body bags out after a horrific fire that happened in the middle of a subzero night. If people want to work with this stuff they should know what the hell their doing. There are books and videos that can teach a homeowner how to put in a 200 amp service and wire the whole house. My neighbor did just that and passed the village electrical inspection he even had a permit.
|