forums
new posts
donate
UER Store
events
location db
db map
search
members
faq
terms of service
privacy policy
register
login




Location DB > United States > Tennessee > Harriman > Martin Farmhouse > beautiful day. > martin farmhouse 011.jpg

9 / 12   martin farmhouse 011.jpg

Description
Controls

Return to Main Location Page

Return to Gallery Overview

Edit this Gallery

Edit this Picture

Subscribe this Picture
Comments
Posted by joespagetti 12/16/2007 8:41 PM | remove
  It's a wonder the place didn't burn down. Yikes!
Posted by THWN2 11/11/2022 1:23 AM | remove
  HM double tapped mains= 125 amps not 60 thats there, 30 amp fuses where there should be only 15 amp & indoor fuse boxes where there should be rain proof 3R boxes? They didnt even bother to use a connector on that UNFUSED jumper between the boxes and some of the branch circuits let alone strapping the cables down, open knockouts. This is an electricians nightmare. This is so dangerous I could just see them carrying the body bags out after a horrific fire that happened in the middle of a subzero night. If people want to work with this stuff they should know what the hell their doing. There are books and videos that can teach a homeowner how to put in a 200 amp service and wire the whole house. My neighbor did just that and passed the village electrical inspection he even had a permit.
If you'd like to add a comment, please login or register.



All content and images copyright © 2002-2024 UER.CA and respective creators. Graphical Design by Crossfire.
To contact webmaster, or click to email with problems or other questions about this site: UER CONTACT
View Terms of Service | View Privacy Policy | Server colocation provided by Beanfield
This page was generated for you in 467 milliseconds. Since June 23, 2002, a total of 739920947 pages have been generated.